-- INTELLECT MODULE. -- Private Enterprise MIB definition -- 16/07/2016 -- This file describes the "Intellect Module" MIB. INODE-SENSE-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress, Gauge, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; DisplayString ::= OCTET STRING -- tree structure -- -- predefined constants for easier definition -- iml OBJECT IDENTIFIER ::= { enterprises 43672 } products OBJECT IDENTIFIER ::= { iml 1 } inode OBJECT IDENTIFIER ::= { products 2 } control OBJECT IDENTIFIER ::= { inode 1 } config OBJECT IDENTIFIER ::= { inode 2 } trapargs OBJECT IDENTIFIER ::= { inode 3 } temperature_sensors OBJECT IDENTIFIER ::= { control 1 } humidity_sensor OBJECT IDENTIFIER ::= { control 2 } discrete_inputs OBJECT IDENTIFIER ::= { control 3 } relay OBJECT IDENTIFIER ::= { control 4 } relayext OBJECT IDENTIFIER ::= { control 5 } inoderelay OBJECT IDENTIFIER ::= { control 6 } com2tcp OBJECT IDENTIFIER ::= { control 7 } -- mind, that before every variable definition you can see its complete -- digital name -- ============================================================== -- Control variables -- ============================================================== --=============================================================== -- Temperature sensors --=============================================================== -- 1.3.6.1.4.1.43672.1.2.1.1.1 temperatureSensorsTable OBJECT-TYPE SYNTAX SEQUENCE OF TempSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Temperature sensors table" ::= { temperature_sensors 1 } TempSensorsEntry ::= SEQUENCE { tempSensorNumber INTEGER, tempSensorConnectStatus INTEGER, tempSensorName DisplayString, tempSensorTMPx10 INTEGER, tempSensorAlarmStatus INTEGER, tempSensorLowLevel INTEGER, tempSensorHighLevel INTEGER } -- 1.3.6.1.4.1.43672.1.2.1.1.1.1 tempSensorsEntry OBJECT-TYPE SYNTAX TempSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Temperature sensors info." INDEX { tempSensorNumber } ::= { temperatureSensorsTable 1 } -- 1.3.6.1.4.1.43672.1.2.1.1.1.1.1 tempSensorNumber OBJECT-TYPE SYNTAX INTEGER(0..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of temperature sensors" ::= { tempSensorsEntry 1 } -- 1.3.6.1.4.1.43672.1.2.1.1.1.1.2 tempSensorConnectStatus OBJECT-TYPE SYNTAX INTEGER { disconnected(0), connected(1) } ACCESS read-only STATUS current DESCRIPTION "Temperature sensor connection status" ::= { tempSensorsEntry 2 } -- 1.3.6.1.4.1.43672.1.2.1.1.1.1.3 tempSensorName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) ACCESS read-write STATUS current DESCRIPTION "Temperature sensor 1 name" ::= { tempSensorsEntry 3 } -- 1.3.6.1.4.1.43672.1.2.1.1.1.1.4 tempSensorTMPx10 OBJECT-TYPE SYNTAX INTEGER (-1000..1500) UNITS "0.1 deg.C" ACCESS read-only STATUS current DESCRIPTION "Temperature sensor current temperature. -1000 - sensor disconnected" ::= { tempSensorsEntry 4 } -- 1.3.6.1.4.1.43672.1.2.1.1.1.1.5 tempSensorAlarmStatus OBJECT-TYPE SYNTAX INTEGER { norm(0), low_alarm(1), high_alarm(2), disconn_alarm(3) } ACCESS read-only STATUS current DESCRIPTION "Temperature sensor alarm status" ::= { tempSensorsEntry 5 } -- 1.3.6.1.4.1.43672.1.2.1.1.1.1.6 tempSensorLowLevel OBJECT-TYPE SYNTAX INTEGER (-55..125) UNITS "deg.C" ACCESS read-write STATUS current DESCRIPTION "Temperature sensor low alarm level" ::= { tempSensorsEntry 6 } -- 1.3.6.1.4.1.43672.1.2.1.1.1.1.7 tempSensorHighLevel OBJECT-TYPE SYNTAX INTEGER (-55..125) UNITS "deg.C" ACCESS read-write STATUS current DESCRIPTION "Temperature sensor high alarm level" ::= { tempSensorsEntry 7 } --=============================================================== -- Temperature sensor disconnect alarm --=============================================================== -- 1.3.6.1.4.1.43672.1.2.1.1.2 tempSensors_DisconnectAlarm OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS current DESCRIPTION "Enable temperature sensors alarm when sensor disconnected" ::= { temperature_sensors 2 } --=============================================================== -- Humidity sensor --=============================================================== -- 1.3.6.1.4.1.43672.1.2.1.2.1 humiditySensorConnectStatus OBJECT-TYPE SYNTAX INTEGER { disconnected(0), connected(1) } ACCESS read-only STATUS current DESCRIPTION "Humidity sensor connection status" ::= { humidity_sensor 1 } -- 1.3.6.1.4.1.43672.1.2.1.2.2 humiditySensorName OBJECT-TYPE SYNTAX DisplayString(SIZE (0..12)) ACCESS read-write STATUS current DESCRIPTION "Humidity sensor name" ::= { humidity_sensor 2 } -- 1.3.6.1.4.1.43672.1.2.1.2.3 humiditySensorTMPx10 OBJECT-TYPE SYNTAX INTEGER (-1000..1500) UNITS "0.1 deg.C" ACCESS read-only STATUS current DESCRIPTION "Humidity sensor current temperature. -1000 - sensor disconnected" ::= { humidity_sensor 3 } -- 1.3.6.1.4.1.43672.1.2.1.2.4 humiditySensorTempAlarmStatus OBJECT-TYPE SYNTAX INTEGER { norm(0), low_alarm(1), high_alarm(2), disconn_alarm(3) } ACCESS read-only STATUS current DESCRIPTION "Humidity sensor temperature alarm status" ::= { humidity_sensor 4 } -- 1.3.6.1.4.1.43672.1.2.1.2.5 humiditySensorTempLowLevel OBJECT-TYPE SYNTAX INTEGER (-55..125) UNITS "deg.C" ACCESS read-write STATUS current DESCRIPTION "Humidity sensor temperature low alarm level" ::= { humidity_sensor 5 } -- 1.3.6.1.4.1.43672.1.2.1.2.6 humiditySensorTempHighLevel OBJECT-TYPE SYNTAX INTEGER (-55..125) UNITS "0.1 deg.C" ACCESS read-write STATUS current DESCRIPTION "Humidity sensor temperature high alarm level" ::= { humidity_sensor 6 } -- 1.3.6.1.4.1.43672.1.2.1.2.7 humiditySensorHUMx10 OBJECT-TYPE SYNTAX INTEGER (0..1000) UNITS "0.1 %" ACCESS read-only STATUS current DESCRIPTION "Humidity sensor current humidity. 0 - sensor disconnected" ::= { humidity_sensor 7 } -- 1.3.6.1.4.1.43672.1.2.1.2.8 humiditySensorHumAlarmStatus OBJECT-TYPE SYNTAX INTEGER { norm(0), low_alarm(1), high_alarm(2), disconn_alarm(3) } ACCESS read-only STATUS current DESCRIPTION "Humidity sensor humidity alarm status" ::= { humidity_sensor 8 } -- 1.3.6.1.4.1.43672.1.2.1.2.9 humiditySensorHumLowLevel OBJECT-TYPE SYNTAX INTEGER (0..100) UNITS "%" ACCESS read-write STATUS current DESCRIPTION "Humidity sensor humidity low alarm level" ::= { humidity_sensor 9 } -- 1.3.6.1.4.1.43672.1.2.1.2.10 humiditySensorHumHighLevel OBJECT-TYPE SYNTAX INTEGER (0..100) UNITS "%" ACCESS read-write STATUS current DESCRIPTION "Humidity sensor humidity high alarm level" ::= { humidity_sensor 10 } --=============================================================== -- Humidity sensor disconnect alarm --=============================================================== -- 1.3.6.1.4.1.43672.1.2.1.2.11 humiditySensorsDisconnectAlarm OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS current DESCRIPTION "Humidity sensor alarm enable when sensor disconnected" ::= { humidity_sensor 11 } --=============================================================== -- Discrete inputs --=============================================================== -- 1.3.6.1.4.1.43672.1.2.1.3.1 dInputsTable OBJECT-TYPE SYNTAX SEQUENCE OF DInputsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete inputs table" ::= { discrete_inputs 1 } DInputsEntry ::= SEQUENCE { dInputNumber INTEGER, dInputName DisplayString, dInputAlarmStatus INTEGER, dInputType INTEGER, dInputAlarmTimer INTEGER } -- 1.3.6.1.4.1.43672.1.2.1.3.1.1 dInputsEntry OBJECT-TYPE SYNTAX DInputsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete inputs info." INDEX { dInputNumber } ::= { dInputsTable 1 } -- 1.3.6.1.4.1.43672.1.2.1.3.1.1.1 dInputNumber OBJECT-TYPE SYNTAX INTEGER(0..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of Discrete inputs" ::= { dInputsEntry 1 } -- 1.3.6.1.4.1.43672.1.2.1.3.1.1.2 dInputName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) ACCESS read-write STATUS current DESCRIPTION "Discrete input name" ::= { dInputsEntry 2 } -- 1.3.6.1.4.1.43672.1.2.1.3.1.1.3 dInputAlarmStatus OBJECT-TYPE SYNTAX INTEGER { norm(0), alarm(1) } ACCESS read-only STATUS current DESCRIPTION "Discrete input alarm status" ::= { dInputsEntry 3 } -- 1.3.6.1.4.1.43672.1.2.1.3.1.1.4 dInputType OBJECT-TYPE SYNTAX INTEGER { no(0), nc(1) } ACCESS read-write STATUS current DESCRIPTION "Discrete input type (normal opened, normal closed)" ::= { dInputsEntry 4 } -- 1.3.6.1.4.1.43672.1.2.1.3.1.1.5 dInputAlarmTimer OBJECT-TYPE SYNTAX INTEGER (0..9) UNITS "seconds" ACCESS read-write STATUS current DESCRIPTION "Discrete input alarm timer" ::= { dInputsEntry 5 } --=============================================================== -- RELAY --=============================================================== -- 1.3.6.1.4.1.43672.1.2.1.4.1 relayName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) ACCESS read-write STATUS current DESCRIPTION "Relay name" ::= { relay 1 } -- 1.3.6.1.4.1.43672.1.2.1.4.2 relayState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS current DESCRIPTION "Relay state" ::= { relay 2 } -- 1.3.6.1.4.1.43672.1.2.1.4.3 relaySource OBJECT-TYPE SYNTAX INTEGER {manual(0), din1(1), din2(2), din3(3), din4(4), din5(5), din6(6), din7(7),din8(8), humidity_low_temp(9), humidity_high_temp(10), humidity_norm_temp(11), humidity_low_hum(12), humidity_high_hum(13), humidity_norm_hum(14), temp1_low(15), temp2_low(16), temp3_low(17), temp4_low(18), temp5_low(19), temp6_low(20), temp7_low(21), temp8_low(22), temp1_high(23), temp2_high(24), temp3_high(25), temp4_high(26), temp5_high(27), temp6_high(28), temp7_high(29), temp8_high(30), temp1_norm(31), temp2_norm(32), temp3_norm(33), temp4_norm(34), temp5_norm(35), temp6_norm(36), temp7_norm(37), temp8_norm(38), ethernet_tcp(39)} ACCESS read-write STATUS current DESCRIPTION "Relay action source" ::= { relay 3 } -- 1.3.6.1.4.1.43672.1.2.1.4.4 relayAction OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), no_action(2) } ACCESS read-write STATUS current DESCRIPTION "Relay action type" ::= { relay 4 } -- 1.3.6.1.4.1.43672.1.2.1.4.5 relayIPaddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "Remote control module IP address" ::= { relay 5 } -- 1.3.6.1.4.1.43672.1.2.1.4.6 relayTCPport OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "TCP port for remote relay control" ::= { relay 6 } -- 1.3.6.1.4.1.43672.1.2.1.4.7 relayPassword OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-write STATUS current DESCRIPTION "Password for remote relay control" ::= { relay 7 } -- 1.3.6.1.4.1.43672.1.2.1.4.8 relayStateRST OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS current DESCRIPTION "Reset relay state if remote module connection lost" ::= { relay 8 } --=============================================================== -- External RELAY --=============================================================== -- 1.3.6.1.4.1.43672.1.2.1.5.1 relayExtState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), off_no_cntrl(128), on_no_cntrl(129), no_connection(144) } ACCESS read-only STATUS current DESCRIPTION "External Relay state" ::= { relayext 1 } -- 1.3.6.1.4.1.43672.1.2.1.5.2 relayExtIPaddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "External relay module IP address" ::= { relayext 2 } -- 1.3.6.1.4.1.43672.1.2.1.5.3 relayExtTCPport OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "External relay module TCP port" ::= { relayext 3 } -- 1.3.6.1.4.1.43672.1.2.1.5.4 relayExtSource OBJECT-TYPE SYNTAX INTEGER {manual(0), din1(1), din2(2), din3(3), din4(4), din5(5), din6(6), din7(7),din8(8), humidity_low_temp(9), humidity_high_temp(10), humidity_norm_temp(11), humidity_low_hum(12), humidity_high_hum(13), humidity_norm_hum(14), temp1_low(15), temp2_low(16), temp3_low(17), temp4_low(18), temp5_low(19), temp6_low(20), temp7_low(21), temp8_low(22), temp1_high(23), temp2_high(24), temp3_high(25), temp4_high(26), temp5_high(27), temp6_high(28), temp7_high(29), temp8_high(30), temp1_norm(31), temp2_norm(32), temp3_norm(33), temp4_norm(34), temp5_norm(35), temp6_norm(36), temp7_norm(37), temp8_norm(38)} ACCESS read-write STATUS current DESCRIPTION "External relay action source" ::= { relayext 4 } -- 1.3.6.1.4.1.43672.1.2.1.5.5 relayExtAction OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), no_action(2) } ACCESS read-write STATUS current DESCRIPTION "External relay action type" ::= { relayext 5 } -- 1.3.6.1.4.1.43672.1.2.1.5.6 relayExtPassword OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-write STATUS current DESCRIPTION "External relay control password" ::= { relayext 6 } --=============================================================== -- Inode RELAY --=============================================================== -- 1.3.6.1.4.1.43672.1.2.1.6.1 inodeRelayIPaddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "inode-relay module IP address" ::= { inoderelay 1 } -- 1.3.6.1.4.1.43672.1.2.1.6.2 inodeRelayTCPport OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "inode-relay module TCP port" ::= { inoderelay 2 } -- 1.3.6.1.4.1.43672.1.2.1.6.3 inodeRelayPassword OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-write STATUS current DESCRIPTION "External relay control password" ::= { inoderelay 3 } -- 1.3.6.1.4.1.43672.1.2.1.6.4 inodeRelayTable OBJECT-TYPE SYNTAX SEQUENCE OF InodeRelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "inode-relay module table" ::= { inoderelay 4 } InodeRelayEntry ::= SEQUENCE { inodeRelayNumber INTEGER, inodeRelayState INTEGER, inodeRelaySource INTEGER, inodeRelayAction INTEGER } -- 1.3.6.1.4.1.43672.1.2.1.6.4.1 inodeRelayEntry OBJECT-TYPE SYNTAX InodeRelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "inode-relay module info." INDEX { inodeRelayNumber } ::= { inodeRelayTable 1 } -- 1.3.6.1.4.1.43672.1.2.1.6.4.1.1 inodeRelayNumber OBJECT-TYPE SYNTAX INTEGER(0..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of inode-relay module relays" ::= { inodeRelayEntry 1 } -- 1.3.6.1.4.1.43672.1.2.1.6.4.1.2 inodeRelayState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), off_no_cntrl(128), on_no_cntrl(129), no_connection(144) } ACCESS read-only STATUS current DESCRIPTION "inode-relay module relays status" ::= { inodeRelayEntry 2 } -- 1.3.6.1.4.1.43672.1.2.1.6.4.1.3 inodeRelaySource OBJECT-TYPE SYNTAX INTEGER {manual(0), din1(1), din2(2), din3(3), din4(4), din5(5), din6(6), din7(7),din8(8), humidity_low_temp(9), humidity_high_temp(10), humidity_norm_temp(11), humidity_low_hum(12), humidity_high_hum(13), humidity_norm_hum(14), temp1_low(15), temp2_low(16), temp3_low(17), temp4_low(18), temp5_low(19), temp6_low(20), temp7_low(21), temp8_low(22), temp1_high(23), temp2_high(24), temp3_high(25), temp4_high(26), temp5_high(27), temp6_high(28), temp7_high(29), temp8_high(30), temp1_norm(31), temp2_norm(32), temp3_norm(33), temp4_norm(34), temp5_norm(35), temp6_norm(36), temp7_norm(37), temp8_norm(38)} ACCESS read-write STATUS current DESCRIPTION "inode-relay module relays action source" ::= { inodeRelayEntry 3 } -- 1.3.6.1.4.1.43672.1.2.1.6.4.1.4 inodeRelayAction OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), no_action(2) } ACCESS read-write STATUS current DESCRIPTION "inode-relay module relays action type" ::= { inodeRelayEntry 4 } --=============================================================== -- COM2TCP --=============================================================== -- 1.3.6.1.4.1.43672.1.2.1.7.1 com2tcpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "COM2TCP module port" ::= { com2tcp 1 } -- 1.3.6.1.4.1.43672.1.2.1.7.2 com2tcpBaudRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "COM2TCP module UART baud rate" ::= { com2tcp 2 } -- ============================================================== -- config variables -- ============================================================== -- 1.3.6.1.4.1.43672.1.2.2.1 date OBJECT-TYPE SYNTAX DisplayString (SIZE (8)) ACCESS read-write STATUS current DESCRIPTION "Date" ::= { config 1 } -- 1.3.6.1.4.1.43672.1.2.2.2 time OBJECT-TYPE SYNTAX DisplayString (SIZE (8)) ACCESS read-write STATUS current DESCRIPTION "Time" ::= { config 2 } -- 1.3.6.1.4.1.43672.1.2.2.3 sntp_sysTimeUpdate_Enable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS current DESCRIPTION "Update time via SNTP" ::= { config 3 } -- 1.3.6.1.4.1.43672.1.2.2.4 timeZone OBJECT-TYPE SYNTAX INTEGER (-12..12) ACCESS read-write STATUS current DESCRIPTION "Time zone" ::= { config 4 } -- 1.3.6.1.4.1.43672.1.2.2.5 sntp_sysTimeUpdate_Period OBJECT-TYPE SYNTAX INTEGER (0..9) UNITS "hours" ACCESS read-write STATUS current DESCRIPTION "SNTP time update period" ::= { config 5 } -- 1.3.6.1.4.1.43672.1.2.2.6 sntp_sysTimeUpdate_Server OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-write STATUS current DESCRIPTION "SNTP server" ::= { config 6 } -- 1.3.6.1.4.1.43672.1.2.2.7 clearLog OBJECT-TYPE SYNTAX INTEGER { clr(1) } ACCESS read-write STATUS current DESCRIPTION "Clear system log" ::= { config 7 } -- ============================================================== -- trap variables -- ============================================================== -- 1.3.6.1.4.1.43672.1.2.3.1 trapCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-write STATUS current DESCRIPTION "Trap community to be used by agent to send trap" ::= { trapargs 1 } -- 1.3.6.1.4.1.43672.1.2.3.2 trapReceiverIPAddress1 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "Trap receiver IP address" ::= { trapargs 2 } -- 1.3.6.1.4.1.43672.1.2.3.3 trapReceiverIPAddress2 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "Trap receiver IP address" ::= { trapargs 3 } -- 1.3.6.1.4.1.43672.1.2.3.4 trapReceiverIPAddress3 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "Trap receiver IP address" ::= { trapargs 4 } -- 1.3.6.1.4.1.43672.1.2.3.5 traps OBJECT-TYPE SYNTAX DisplayString (SIZE (0..99)) ACCESS read-only STATUS current DESCRIPTION "Trap notification information for the SNMP Manager." ::= { trapargs 5 } -- 1.3.6.1.4.1.43672.1.2.3.6 traps_level OBJECT-TYPE SYNTAX INTEGER {message(0), warning(1), alarm(2)} ACCESS read-only STATUS current DESCRIPTION "Trap notification level for the SNMP Manager." ::= { trapargs 6 } -- 1.3.6.1.4.1.43672.1.2.4 name OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS current DESCRIPTION "Product name" ::= { inode 4 } --===================================================================== -- Traps Definitions start --===================================================================== relay_Off TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Relay: Off" ::= 1 relay_On TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Relay: On" ::= 2 relayExternal_Off_command TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "External Relay: Off command" ::= 3 relayExternal_On_command TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "External Relay: On command" ::= 4 relayExternal_Off TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "External Relay: Off" ::= 5 relayExternal_On TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "External Relay: On" ::= 6 relayExternal_Off_NoControl TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "External Relay: Off (no control)" ::= 7 relayExternal_On_NoControl TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "External Relay: On (no control)" ::= 8 relayExternal_Disconnected TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "External Relay: disconnected" ::= 9 relayControlModule_Disconnected TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Relay control module: disconnected" ::= 10 relayControlModule_Connected TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Relay control module: connected" ::= 11 relayControlModule_OffCommand TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Relay control module: Off command" ::= 12 relayControlModule_OnCommand TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Relay control module: On command" ::= 13 inodeRelay_Off_command TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "inode-relay module Relay: Off command" ::= 14 inodeRelay_On_command TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "inode-relay module Relay: On command" ::= 15 inodeRelay_Off TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "inode-relay module Relay: Off" ::= 16 inodeRelay_On TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "inode-relay module Relay: On" ::= 17 inodeRelay_Off_NoControl TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "inode-relay module Relay: Off (no control)" ::= 18 inodeRelay_On_NoControl TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "inode-relay module Relay: On (no control)" ::= 19 inodeRelay_Disconnected TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "inode-relay module Relay: disconnected" ::= 20 dInput_Alarm TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Discrete input X: alarm" ::= 25 dInput1_EndAlarm TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Discrete input X: end alarm" ::= 26 tempSensor_Disconnected TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Temperature sensor X: disconnected" ::= 40 tempSensor_LowAlarm TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Temperature sensor X: low alarm" ::= 41 tempSensor_HighAlarm TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Temperature sensor X: high alarm" ::= 42 tempSensor_Connected TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Temperature sensor X: connected" ::= 43 tempSensor_EndAlarm TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Temperature sensor X: end alarm" ::= 44 humiditySensor_Disconnected TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Humidity sensor: disconnected" ::= 50 humiditySensor_TempLowAlarm TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Humidity sensor temperature: low alarm" ::= 51 humiditySensor_TempHighAlarm TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Humidity sensor temperature: high alarm" ::= 52 humiditySensor_HumLowAlarm TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Humidity sensor humidity: low alarm" ::= 53 humiditySensor_HumHighAlarm TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Humidity sensor humidity: high alarm" ::= 54 humiditySensor_Connected TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Humidity sensor: connected" ::= 55 humiditySensor_TempEndAlarm TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Humidity sensor temperature: end alarm" ::= 56 humiditySensor_HumEndAlarm TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Humidity sensor humidity: end alarm" ::= 57 relayConfigChanged TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Relay configuration changed" ::= 80 relayExtConfigChanged TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "External Relay configuration changed" ::= 81 dInputsConfigChanged TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Discrete inputs Configuration changed" ::= 82 SensorsConfigChanged TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Sensors Configuration changed" ::= 83 inodeRelayConfigChanged TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "inode-relay module configuration changed" ::= 84 COMtoTCPbridgeConfigChanged TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "COm to TCP Bridge Configuration changed" ::= 86 snmpConfigChanged TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "SNMP Configuration changed" ::= 87 paramsConfigChangedSNMP TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Parameters changed (by SNMP module)" ::= 88 testEmailSent TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Test Email message sent" ::= 89 testEmailError TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Test Email message error" ::= 90 sysTimeConfigChanged TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Time Configuration changed" ::= 91 sntpSysTimeUpdated TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Time updated with SNTP server" ::= 92 networkConfigChanged TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Network Configuration changed" ::= 93 securityConfigChanged TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Name, Password changed" ::= 94 inodePowerON TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "INODE POWER ON" ::= 97 defaultConfig TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Reset parameters to defaults" ::= 98 logClear TRAP-TYPE ENTERPRISE iml VARIABLES { traps, traps_level } DESCRIPTION "Log Clear" ::= 99 END